Choice of scales, temperatures, operating modes and GLP are at your fingertips with the PTR 46 series. Versatility is the main feature of the PTR 46 and 46X models. The 46 button keypad, with dedicated function and alpha-numeric keys in the standard "Qwerty" layout, gives easy access to the many programmable features of these models.

Available for the sugar industry is the PTR 46X, which measures apparent sugar purity when connected to an Optical Activity Polarimeter.

A simple key press gives access to up to 14 scales; refractive index (RI), Brix (% of sucrose), temperature corrected Brix, temperature corrected RI, and up to 10 user programmable scales. You also have a choice of measuring modes: in Continuous mode, the PTR reads all the time and samples can be read in the same way as the PTR 2 model. Single Scan mode allows you to program the instrument to wait a pre-set time to allow for stabilization and then to scan, display, and hold the result. By selecting AutoPrint mode, the operator can set a time interval for automatic print-outs to monitor a changing or flowing sample. In Stability mode the automatic measuring system within the instrument intelligently decides when the sample has come to a stable reading, and only then outputs the result. The operator can set the level of stability to ensure that the accuracy required is obtained time after time, in the shortest possible time.

The "Qwerty" format keypad on the PTR 46 series makes entering "GLP" (Good Laboratory Practice) data, straightforward. Time, date, and instrument serial number can be output to a printer or computer along with every reading, and the instrument can also be set up to ask for a number, or up to 6 other parameters specified by the user, to fully identify the sample. The titles of these parameters can have up to 20 characters (letters, numbers, or spaces) and can be in any language.

The PTR 46 DL is the latest instrument design.

 
PTR 46
PTR 46X
  PTR 46XP

Scales:

Refractive Index (RI), Brix (% of sucrose), or Temperature Corrected Brix. Ten user programmable scales and user programmable temperature corrected RI.
 
Refractive Index (RI), Brix (% of sucrose), or Temperature Corrected Brix. Ten user programmable scales and user programmable temperature corrected RI.
  Refractive Index (RI), Brix (% of sucrose), Temperature Corrected Brix. Apparent sugar purity when connected to an Optical Activity polarimeter.
Range:
RI 1.32 to 1.68, Brix 0 to 100%
 
RI 1.32 to 1.68, Brix 0 to 100%
  RI 1.32 to 1.68, Brix 0 to 100%
Readability:
RI 0.0001, Brix 0.1%
 
RI 0.00001, Brix 0.01%
  RI 0.00001, Brix 0.01%
Accuracy:
RI ± 0.0001, Brix ± 0.1%
 
± 0.00005 RI , 1.32 to 1.45 RI;
± 0.05 Brix , 0 to 65% Brix
  ± 0.0001RI , 1.45 to 1.68 RI;
± 0.01 Brix , 65 to 100% Brix
Wavelength:
Sodium Yellow 589nm
 
Sodium Yellow 589nm
  Sodium Yellow 589nm
Readout Time:
Approx. 3 seconds (continuous update)
 
Approx. 9 seconds (continuous update)
  Approx. 9 seconds (continuous update)
Temperature Control:
Internal electronic control by Peltier cell
 
Internal electronic control by Peltier cell
  Internal electronic control by Peltier cell
Temperature Stability:
± 0.015°C
 
± 0.015°C
  ± 0.015°C
Temperature Accuracy:
± 0.1°C at 20°C Thermometer resolution: 0.1°C
 
± 0.05°C at 20°C Thermometer resolution: 0.01°C
  ± 0.05°C at 20°C Thermometer resolution: 0.01°C

Sample
Temperature Control Range:

15°C to 50°C
 
15°C to 50°C
  15°C to 50°C
Working Ambient
Temperature Range:
10°C to 35°C PTR will control without assistance 10°C below ambient to 20°C above ambient
 
10°C to 35°C PTR will control without assistance 10°C below ambient to 20°C above ambient
  10°C to 35°C PTR will control without assistance 10°C below ambient to 20°C above ambient
Controls:
46 key membrane including function keys, digits, alphabet 'qwerty' format
 
46 key membrane including function keys, digits, alphabet 'qwerty' format
  46 key membrane including function keys, digits, alphabet 'qwerty' format
Special Features:
Choice of operating modes: continuous, single scan with user programmable delay time or STABILITY FEATURE read when stable.Touch button selection of normal or emulsion type sample   Choice of operating modes: continuous, single scan with user programmable delay time or STABILITY FEATURE read when stable.Touch button selection of normal or emulsion type sample   Choice of operating modes: continuous, single scan with user programmable delay time or STABILITY FEATURE read when stable.Touch button selection of normal or emulsion type sample
Display:
Back-lit liquid crystal display with contrast control
 
Back-lit liquid crystal display with contrast control
  Back-lit liquid crystal display with contrast control
Light Source:
LED
 
LED
  LED
Prism Material:
Synthetic Sapphire
 
Synthetic Sapphire
  Synthetic Sapphire
Outputs/Inputs:
2 x RS232; 1 x remote
 
2 x RS232; 1 x remote
  2 x RS232; 1 x remote
Data Output Available:
Scale, reading, temperature, time, date, serial #, sample #, up to 6 specified GLP (Good Laboratory Practice) identifiers, bar code (user selectable)   Scale, reading, temperature, time, date, serial #, sample #, up to 6 specified GLP (Good Laboratory Practice) identifiers, bar code (user selectable)   Scale, reading, temperature, time, date, serial #, sample #, up to 6 specified GLP (Good Laboratory Practice) identifiers, bar code (user selectable)
Power Requirements:
86 to 265 v ac; 47 to 63 Hz nominal; less than 30 watts
 
86 to 265 v ac; 47 to 63 Hz nominal; less than 30 watts
  86 to 265 v ac; 47 to 63 Hz nominal; less than 30 watts
Dimensions
(w x d x h):
Refractometer: 258 x 290 x 160mm, Power supply: 80 x 180 x 60mm
 
Refractometer: 258 x 290 x 160mm, Power supply: 80 x 180 x 60mm
  Refractometer: 258 x 290 x 160mm, Power supply: 80 x 180 x 60 mm
Weight:
Refractometer: 5.7kg, Power supply: 0.8kg
 
Refractometer: 5.7kg, Power supply: 0.8kg
Refractometer: 5.7kg, Power supply: 0.8kg
Packed Weight:
Approx. 10kg   Approx. 10kg   Approx. 10kg

 
Associated with


3305 Commerce Blvd.
Kissimmee, FL 34741
 

Phone: 407-932-3688
Fax: 407-932-3686
IndexUS@aol.com
 
We Accept Visa and Mastercard
 
*Due to continuing research and technical advances, we reserve the right to alter the product specifications of any of the products on our web site.