Offers high quality, high accuracy, high reliability, clear digital display, flexibility of use, plus detailed GLP traceability of results. It's all metal construction is based on a incredibly stable aluminum casing with metal covers. The principle of measurement used in the PolAAr 3 series was patented by Optical Activity, Ltd. in 1976, and the original advanced design, which won a Queen's Award for Technology Achievement, has been refined by Optical Activity through many years of experience in polarimetry.

All models in the PolAAr 3 series accept the full range of activity polarimeter sample tubes and cells from 1.5mm to 8mm bore, from 5mm to 200mm path length, jacketed or unjacketed. The sample compartment is ventilated to minimize temperature rise above ambient. For the most accurate temperature control, jacketed sample tubes are available for temperature control from a thermocirculator. These tubes are available with built in temperature sensors to accurately monitor sample temperature. A dip-in thermometer is available for use with single sample tubes.

The difference between the PolAAr 31 and the PolAAr 3001 is the resolution. The PolAAr 3001 is our highest accuracy model. It reads to 0.001 angular degrees of optical rotation and displays results within 25 seconds. When connected to an Index Instruments refractometer the PolAAr 3001 combine the ISS and Brix readings and calculate and display apparent sugar purity.

 
PolAAR 35
PolAAR 3005

Scales:

Angular degrees, ISS (°Z) temperature corrected °Z, specified rotation, concentration, 10 user programmable scales, apparent sugar purity if connected to an Index Instruments refractometer
Angular degrees, ISS (°Z) temperature corrected °Z, specified rotation, concentration, 10 user programmable scales, apparent sugar purity if connected to an Index Instruments refractometer
Range:
Full circle, reading ± 90 angular degrees, in excess of ± 130°Z
Full circle, reading ± 90 angular degrees, in excess of ± 130°Z
Accuracy:
± 0.01°, ± 0.02°
± 0.001°(0-10°), ± 0.01° Z (0-25°Z) ± 0.01° (10-90°), ± 0.02° (above 25°Z) or equivalent in other scales
Wavelength:
589, 546, 436, 405 and 365nm (other wavelengths are available)
589, 546, 436, 405 and 365nm (other wavelengths are available)
Light Source:
20 watt tungsten halogen lamp
20 watt tungsten halogen lamp
Outputs/Inputs:
2 x RS232 (25-way D sockets); 1 x remote (9-way D sockets)
2 x RS232 (25-way D sockets); 1 x remote (9-way D sockets)
OD Tolerance:
365nm OD 1.5 (97% absorbance), 546nm & 589nm OD 3.0 (99.9% absorbance), 880nm OD 4.5 (99.997% absorbance) 365nm OD 1.5 (97% absorbance), 546nm & 589nm OD 3.0 (99.9% absorbance), 880nm OD 4.5 (99.997% absorbance)
Readout Time:
10 sec
25 sec
Operating Modes:
Continuous, Autoprint (reads continuously, outputs at set times or on data change), One shot and lock (user sets readout time, display locked after time delay), or Stability (readout when stable, user sets stability parameters) Continuous, Autoprint (reads continuously, outputs at set times or on data change), One shot and lock (user sets readout time, display locked after time delay), or Stability (readout when stable, user sets stability parameters)
Sample Compartment:
Accepts standard sample tubes, 30mm diameter collars. Maximum path length 200mm, bores 8mm down to 1.5mm Accepts standard sample tubes, 30mm diameter collars. Maximum path length 200mm, bores 8mm down to 1.5mm
Thermometers:
Temperature sensor in sample compartment, socket for alternative sample tube sensor. Sensor range 0 to 100°C, accuracy ± 0.25°C. Digital display resolution 0.1°C. Temperature sensor in sample compartment, socket for alternative sample tube sensor. Sensor range 0 to 100°C, accuracy ± 0.25°C. Digital display resolution 0.1°C.
Data Output:
Rotation reading, units, time and date, polarimeter serial number, wavelength, temperature, pre-set parameters, sample number   Rotation reading, units, time and date, polarimeter serial number, wavelength, temperature, preset parameters, sample number
Special Features:
User selection and definition of output parameters for GLP (Good Laboratory Practice): in addition to the standard data output, up to 6 user defined sample identifiers User selection and definition of output parameters for GLP (Good Laboratory Practice): in addition to the standard data output, up to 6 user defined sample identifiers
Controls:
Power ON/OFF, Alpha-numeric keypad, plus function keys including print, zero and scale selection
Power ON/OFF, Alphanumeric keypad, plus function keys including print, zero and scale selection
Calibration:
UKAS calibration certificate available if required (order code 10-01) UKAS calibration certificate available if required (order code 10-01)
Power Requirements:
86 to 265 v ac; 47 to 63 Hz, 40 watts maximum 86 to 265 v ac; 47 to 63 Hz, 40 watts maximum
Dimensions
(w x d x h):
515 x 380 x 198mm
515 x 380 x 198mm
Weight:
15.7kg
15.7kg
Packed Weight:
Approx. 23kg Approx. 23kg

 