This
popular general purpose refractometer gives a wide refractive
indexes (RI) and temperature ranges making it ideal for applications
in the essential oil, crude oil, and edible oil industries.
The GPR 12-70 is also perfect for measuring sugars, fruit
juices, drinks, solvents, thick pastes pharmaceutical products,
plastics, and any other product which requires quality control
for RI or concentration. Also, this instrument includes improved
software, can be measured up to 70°C, contains synthetic
sapphire prism and LED light source for long life, is less
than 24cm wide, has a waterproof construction which was designed
for easy cleaning, and includes many more handy features and
accessories.

We
now offer a higher accuracy general purpose instrument with
similar features to our popular GPR 12-70 refractometer. The
GPR 53X offers a 5th decimal place resolution of Refractive
Index (RI) and a 2nd decimal place resolution of Brix (% of
sucrose). This model covers the full Brix range required by
the sugar industry (0 to 95%). The GPR 53X also comes with
the latest software that includes intelligent monitoring of
when the sample reading has reached stability, sample numbering
and time, date and serial number output for traceability,
and more. More features include a user friendly 16 button
keypad, a waterproof construction which was designed for easy
cleaning, a compact design with a small footprint (less than
24cm wide), a wide temperature range (5°C up to 70°C),
contains synthetic sapphire prism and LED light source for
long life, and includes many more handy features.
|
|
|
|
GPR
12-70
|
 |
GPR
53X
|
 |
GPR
12-70X |
|
Scales:
|
Touch button selection of Refractive Index (RI).
Brix (% of sucrose), Temperature Corrected Brix,
10 user programmable scales or user programmable
Temperature Corrected RI scale
|
|
Refractive Index (RI), Brix, Temperature Corrected
Brix, 10 user programmable scales and user programmable
Temperature Corrected RI scale
|
|
Touch
button selection of Refractive Index (RI). Brix
(% of sucrose), Temperature Corrected Brix, 10
user programmable scales or user programmable
Temperature Corrected RI scale
|
|
Range:
|
RI
1.32 to 1.68, Brix 0 to 100%
|
|
RI 1.33 to 1.53, Brix 0 to 95%
|
|
RI
1.32 to 1.68, Brix 0 to 100%
|
|
Readability:
|
RI
0.0001, Brix 0.1%
|
|
RI 0.00001, Brix 0.01%
|
|
RI
0.00001, Brix 0.01%
|
|
Accuracy:
|
RI ± 0.0001 Brix ± 0.1%
|
|
RI
± 0.00003@1.33, Brix ± 0.02@0%
|
|
RI
± 0.00005, 1.33 to 1.45; ± 0.0001, 1.45 to 1.68
± 0.05 Brix, 0 to 65%; ± 0.1 Brix, 65 to 100%
|
|
Wavelength:
|
589nm
|
|
589nm
|
|
589nm
|
|
Readout
Time:
|
Approx. 2 seconds
|
|
Approximately
1 second, depending on resolution
|
|
2
to 6 seconds, depending on resolution
|
|
Temperature:
|
Displayed continuously to 0.1°C with sample
reading; calibrated to ± 0.1°C at 20°C;
|
|
Displayed
continuously to 0.1°C with sample reading;
calibrated to ± 0.1°C at 20°C;
|
|
Displayed
continuously to 0.1°C with sample reading;
calibrated to ± 0.1°C at 20°C;
|
|
Temperature
Accuracy:
|
worst
case deviation in absolute accuracy over entire
range ± 0.5°C |
|
worst
case deviation in absolute accuracy over entire
range ± 0.5°C |
|
worst
case deviation in absolute accuracy over entire
range ± 0.5°C |
|
Thermostatic
Control:
|
By use of circulating fluid, temperature range
5°C to 70°C
|
|
By use of circulating fluid, temperature range
5°C to 70°C
|
|
By
use of circulating fluid, temperature range 5°C
to 70°C
|
|
Controls:
|
Set zero; print; keyboard for programming functions
|
|
Set zero; print; keyboard for programming functions
|
|
Set
zero; print; keyboard for programming functions
|
|
Special
Features:
|
Automatic
detection of reading stability
|
|
|
|
Automatic
detection of reading stability
|
|
Display:
|
Illuminated alphanumeric, 2 lines of 24 characters;
high contrast LCD with contrast control
|
|
Illuminated alphanumeric, 2 lines of 24 characters;
high contrast LCD with contrast control
|
|
Illuminated alphanumeric, 2 lines of 24 characters;
high contrast LCD with contrast control
|
|
Light
Source:
|
LED
|
|
LED
|
|
LED
|
|
Prism
Material:
|
Synthetic
Sapphire
|
|
Synthetic
Sapphire
|
|
Synthetic
Sapphire
|
|
Outputs/Inputs:
|
2
x RS232; 1 x remote
|
|
2
x RS232; 1 x remote
|
|
2
x RS232; 1 x remote
|
|
Data
Output Available:
|
Scale,
reading, temperature, time, date, serial #, sample
#, up to 6 specified GLP (Good Laboratory Practice)
identifiers, bar code (user selectable)
|
|
Scale,
reading, temperature, time, date, serial #, sample
#, up to 6 specified GLP (Good Laboratory Practice)
identifiers, bar code (user selectable)
|
|
Scale,
reading, temperature, time, date, serial #, sample
#, up to 6 specified GLP (Good Laboratory Practice)
identifiers, bar code (user selectable)
|
|
Power
Requirements:
|
86
to 265 v ac; 47 to 63 Hz nominal; less than 7
watts
|
|
86
to 265 v ac; 47 to 63 Hz nominal; less than 7
watts
|
|
86
to 265 v ac; 47 to 63 Hz nominal; less than 7
watts
|
|
Dimensions
(w x d x h):
|
Refractometer: 235 x 260 x 255mm, Power supply:
80 x 160 x 55mm
|
|
Refractometer: 235 x 260 x 255mm, Power supply:
80 x 160 x 55mm
|
|
Refractometer: 235 x 260 x 255mm, Power supply:
80 x 160 x 55mm
|
|
Weight:
|
Refractometer:
8 kg, Power supply: 0.5kg
|
|
Refractometer:
8 kg, Power supply: 0.5kg
|
|
Refractometer:
8 kg, Power supply: 0.5kg
|
|
Packed Weight:
|
12kg
|
|
12kg
|
|
12kg
|
|
Dimensions
of Pack:
|
50
x 40 x 35cm
|
|
50
x 40 x 35cm
|
|
50
x 40 x 35cm
|
|
|