AA-5
Angular
|
 |
AA-5
Sugar
|
 |
AA-5
Switchable |
|
Scales:
|
Degrees
|
|
ISS
|
|
Degrees
and ISS
|
|
Range:
|
±
90°
|
|
± 130° Z
|
|
±
90°, ± 130° Z
|
|
Resolution:
|
0.01°
|
|
0.01°Z
|
|
0.01
both scales
|
|
Accuracy:
|
± 0.05%
|
|
±
0.1%Z
|
|
±
0.05%, ± 0.1%Z
|
|
Wavelength:
|
589.44nm
|
|
589.44nm
|
|
589.44nm
|
|
Light
Source:
|
Nominal 4 watt tungsten lamp, average life in
excess of 2000 hrs.
|
|
Nominal 4 watt tungsten lamp, average life in
excess of 2000 hrs.
|
|
Nominal 4 watt tungsten lamp, average life in
excess of 2000 hrs.
|
|
Digital
Display:
|
0.4"
(9mm) LED's
|
|
0.4"
(9mm) LED's
|
|
0.4"
(9mm) LED's
|
|
Readout
Time:
|
Approx. 6-10 seconds
|
|
Approx.
6-10 seconds
|
|
Approx.
6-10 seconds
|
|
Sample
Compartment:
|
Accepts standard polarimeter tubes with 30mm circular
ends. Maximum path length 200mm
|
|
Accepts standard polarimeter tubes with 30mm circular
ends. Maximum path length 200mm
|
|
Accepts standard polarimeter tubes with 30mm circular
ends. Maximum path length 200mm
|
|
Controls:
|
Power
ON/OFF SET ZERO button. Switchable scale model
has side switch to select scale
|
|
Power
ON/OFF SET ZERO button. Switchable scale model
has side switch to select scale
|
|
Power
ON/OFF SET ZERO button. Switchable scale model
has side switch to select scale
|
|
Special
Features:
|
Display will flash if sample transmittance is
less than 3%, i.e. sample density in excess of
OD 1.5
|
|
Display will flash if sample transmittance is
less than 3%, i.e. sample density in excess of
OD 1.5
|
|
Display will flash if sample transmittance is
less than 3%, i.e. sample density in excess of
OD 1.5
|
|
Optional
Feature :
|
RS232
serial port: Fitted to the instrument. The results
will automatically be printed out or be sent directly
to a computer for inclusion in a software package.
|
|
RS232
serial port: Fitted to the instrument. The results
will automatically be printed out or be sent directly
to a computer for inclusion in a software package.
|
|
RS232
serial port: Fitted to the instrument. The results
will automatically be printed out or be sent directly
to a computer for inclusion in a software package.
|
|
Power
Requirements:
|
AC
line voltage 230v ± 20% or 115v ± 20%, 45 to 65Hz,
10 watts EMC and Low Voltage Directives CE marked
complies with the following regulations 89/336/EEC
as amended by 9168/EEC Electromagnetic Compatibility
Directive (EMC) and 93/68/EEC Low Voltage Directive
|
|
AC
line voltage 230v ± 20% or 115v ± 20%, 45 to 65Hz,
10 watts EMC and Low Voltage Directives CE marked
complies with the following regulations 89/336/EEC
as amended by 9168/EEC Electromagnetic Compatibility
Directive (EMC) and 93/68/EEC Low Voltage Directive
|
|
AC
line voltage 230v ± 20% or 115v ± 20%, 45 to 65Hz,
10 watts EMC and Low Voltage Directives CE marked
complies with the following regulations 89/336/EEC
as amended by 9168/EEC Electromagnetic Compatibility
Directive (EMC) and 93/68/EEC Low Voltage Directive
|
|
Dimensions
(w x d x h):
|
460 x 220 x 110 mm
|
|
460 x 220 x 110 mm
|
|
460 x 220 x 110 mm
|
|
Weight:
|
7.5kg
|
|
7.5kg
|
|
7.5kg
|
|
Packed Weight:
|
12kg
|
|
12kg
|
|
12kg
|